Installation Equipments Terminal Boxes HLBH02-Series Terminal Boxes

Applicable scope

Zone 0 , Zone 1 and Zone 2
Zone 21 and Zone 22
Meet the necessities in the following industries, such as petroleum, chemical, electricity, medicine, textile, wine-making, aerospace, military, fire-fighting, etc.

Features and benefits

◆ Explosion protection to
-CENELEC
-IEC
◆ Stainless steel enclosure.
◆ Weidmuller SAK EN series terminals,Phoenix UK series terminals.

Catalogue number logic

Technical data


Terminal boxes HLBH02-Series
   Explosion protection 
      Gas explosion protection            II2 G Ex e IIC T6 or T5 Gb                     II1 G Ex ia IIC T6 Ga
      Dust explosion protection            II2 D Ex tb IIΙC T80℃ Db ΙP66
   Conformity to standards   EN 60079-0:2012, EN 60079-7:2007, EN 60079-11:2012, EN 60079-31:2009
   IEC 60079-0:2011, IEC 60079-7:2006, IEC 60079-11:2011, IEC 60079-31:2008
   Enclosure material   Stainless steel
   Terminal   Weidmuller SAK EN series
   Phoenix UK series
   Ex-mark:           II2 GD Ex e II
   Exposed fastener   Stainless steel
   Rated voltage   Max.690VAC
   Rated current   Cross section2.5mm2  4mm26mm210mm2  16mm2  35mm2
   Ex e Rated current24A32A41A57A76A125A
   Ex ia Rated current5A5A----
   Degree of protection   IP66
   Ambient temperature   For increased safety terminal box:T6 for Tamb:-40℃~+40℃; T5 for Tamb:-40℃~+55℃
   For intrinsic safety terminal box:T6 for Tamb:-40℃~+55℃
    Note125A on request. height=26 width=678 style="color:#000000;font-size:11.0pt;font-weight:400;font-style:normal;text-decoration:none;text-align:left;vertical-align:middle;white-space:normal;border-left: .5pt solid #000000;border-right: .5pt solid #000000;border-top: .5pt solid #000000;border-bottom: .5pt solid #000000;mso-protection:locked visible;height:19.50pt;width:508.50pt;">   1. Ex e  Rated current > 125A on request.
   2. No cable entries for standard design. Cable entries shall be drilled by user.
   3. For cable entries:
       1) Please specify the direction and size of each cable entry.
       2) Cable gland is optional.
 

Dimension drawings(all dimensions in mm)-subject to alteration

Selection table of HLBH02-Series terminal boxes

Max. cross section of cable connected to terminals is 35mm2,See table for max. number of fitted terminals.
Outline Mounting rail×teminals(Specification and quantities)Ways ofoutletTable of max. number of possible enclosureentries with cable glands BDM-7
 2.524262102162352  
 UK3NUK5NUK6NUK10NUK16NUK35N M16M20M25M32M40M50M63
 SAK2.5ENSAK4ENSAK6ENSAK10ENSAK16ENSAK35EN        
1×141×121×9------D/X865321--
       L/R865321--
1×211×181×131×111×8--D/X12108432--
       L/R865321--
1×271×231×181×141×121×9D/X161210433--
       L/R1088322--
2×272×231×181×141×121×9D/X161210433--
       L/R161210433--
1×371×311×251×201×181×11D/X18/3616/2114/215/104/84/6--/4
       L/R12/2410/158/123/63/42/3--/2
2×372×311×251×201×181×11D/X18/3616/2114/215/104/84/6--/4
       L/R16/3214/2112/185/104/63/5--/3
2×522×431×331×251×221×18D/X24/4820/3018/277/145/104/8--/5
       L/R18/3616/2114/215/104/84/6--/4
3×523×432×332×252×221×18D/X24/48/6620/30/5018/27/357/14/285/10/154/8/12--/5/8
       L/R24/48/6620/30/5018/27/357/14/285/10/154/8/12--/5/8
6×526×432×662×502×441×36D/X48/9240/6036/5414/2810/208/10--/8
       L/R24/4820/3018/277/145/104/8--/5
6×526×432×662×502×441×36D/X138/161100/12083/10242/5630/4020/2515/20
       L/R66/7750/6027/5428/3015/2012/168/10
12×5212×4312×664×504×443×36D/X92/16160/12054/10228/5620/4010/258/20
       L/R92/16160/12054/10228/5620/4010/258/20

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.